Guardian Angel Anchor
Personal Fall Arrest: Angel Anchors may be used to support a MAXIMUM 1 Personal Fall Arrest System (PFAS) for use in Fall Arrest applications. Structure must withstand loads applied in the directions permitted by the system of at least 5,000 lbs. Maximum free fall is 6‘, or up to 12’ if used in combination with equipment
explicitly certified for such use. Applicable D-ring: Dorsal.
Restraint: Angel Anchors may be used in Restraint applications. Restraint systems prevent workers from
reaching the leading edge of a fall hazard. Always account for fully deployed length of lanyard/SRL. Structure must withstand loads applied in the directions permitted by the system of at least 1,000 lbs. No free fall is permitted. Restraint systems may only be used on surfaces with slopes up to 4/12 (vertical/horizontal).
Applicable D-rings: Dorsal, Chest, Side, Shoulder.
For all applications: worker weight capacity range (including all clothing, tools, and equipment) is 130-220 lbs.